一、執行標準standard:
企業標準Enterprise’s standard
二、適用范圍Applications:
DZYJ-WZR(A、B)-125型電纜適于地鐵隧道.車站等相對密閉、人員集中、以及阻燃.且燃燒時不生產濃煙、無毒.要求苛刻的環境下使用,特別適合于隧道配電柜與地鐵間的引線。
Suitable for subway.tunnel.station etc with crowded people wherever requires higher flame-residence less amount of smoke and poisonous when burning halogen gas.Especially suitable for installation and laid wire between power cabinet and railway in tunnel.
三、使用特性Properties:
1.產品型號:DZYJ-WZR(A、B)-125(具體規格參見附表)
Model:DZYJ-WZR-125(details see the attached table)
2.額定電壓750V.1500V
Rated voltage:750V.1500V。3.標稱截面0.5--400mm2
Nominal cross section:0.5-400rnm2
4.導體長期工作溫度125℃,短路過載溫度可達到250℃(5s)
Long-term working temperature is 125℃.Max.working temperature 0f the conductors in short-circuit is 250℃.(5S)
5.電氣性能物理機械性能優異
Good electrical insulation.physical mechanical properties.
6.電纜阻燃性能達到GB/T18380.1-2001中DZ-1法的要求
Flame-residence conforms to DZ-1 of in GBl8380.1-2001
7.低煙無鹵特性:(1)導電率≤10μs/mm
(2)滿足GB/T1 7651—1 998標準要求.其透光率≥60%
(3)PH值≥4.3
Low smoke non-halogen property:(1)Conductivity≤1 O μs/mm
(2)Density transparence of cable flaming smoke≥60% conforming
to GB/T17651—1998
(3)PH≥4.3
8.煙氣毒性符合GAl32準安全級的要求。
Smoke poisonous conform to GAl32.
地鐵隧道專用電纜結構參數表Cable construction
序號 No |
標稱截面 |
線芯結構 |
電纜最大外徑 mm |
電纜參考重量 kg / km |
20 ℃ 時導體電阻 |
||
750V |
1500V |
750V |
1500V |
||||
1 |
0.5 |
16 / 0.2 |
3.60 |
4.20 |
14 |
16 |
40.1 |
2 |
O.75 |
19 / O.23 |
3.80 |
4.40 |
17 |
19 |
25.6 |
3 |
1.0 |
19 / 0.26 |
4.10 |
5.00 |
23 |
26 |
19.9 |
4 |
1.5 |
19 / O.32 |
4.50 |
5.30 |
31 |
33 |
12.8 |
5 |
2.5 |
19 / 0.41 |
5.20 |
6.00 |
40 |
44 |
7.74 |
6 |
4.O |
19 / 0.52 |
6.00 |
6.80 |
61 |
66 |
4.97 |
7 |
6.0 |
19 / 0.64 |
6.70 |
7.40 |
85 |
91 |
3.35 |
8 |
10 |
49 / 0.52 |
8.30 |
9.10 |
138 |
150 |
1.95 |
9 |
16 |
49 / 0.64 |
9.40 |
10.8 |
196 |
210 |
1.24 |
10 |
25 |
98 / O.58 |
11.3 |
12.1 |
296 |
313 |
0.78 |
11 |
35 |
133 / O.58 |
12.9 |
13.7 |
414 |
434 |
O.557 |
12 |
50 |
133 / 0.68 |
14.6 |
15.0 |
548 |
570 |
O.414 |
13 |
70 |
189 / O.68 |
16.0 |
16.4 |
760 |
786 |
0.227 |
14 |
95 |
259 / O.68 |
18.2 |
18.6 |
993 |
1021 |
0.210 |
15 |
120 |
259 / O.76 |
20.2 |
20.6 |
1250 |
1288 |
0.164 |
16 |
150 |
336 / O.74 |
22.2 |
22.6 |
1538 |
1576 |
O.132 |
17 |
185 |
427 / 0.74 |
24.8 |
25.2 |
1 846 |
1901 |
O.108 |
18 |
240 |
427 / 0.85 |
28.4 |
28.8 |
2446 |
2468 |
0.0817 |
19 |
300 |
518 / O.85 |
32.2 |
32.8 |
2995 |
3042 |
0.0654 |
20 |
400 |
703 / 0.85 |
36.4 |
36.8 |
4530 |
4613 |
0.0490 |
Continuous loading current of cable laid in air
截面 mm 2 |
DZY-WZR( A 、 B)-750V |
DZY-WZR(A 、 B)-1 500V |
||
接觸 Contact |
非接觸 Non contact |
接觸 Contact |
非接觸 Noncontact |
|
0.5 |
12 |
19 |
13 |
19 |
0.75 |
24 |
16 |
25 |
17 |
1.0 |
28 |
18 |
29 |
20 |
1.5 |
35 |
23 |
36 |
25 |
2.5 |
47 |
32 |
49 |
34 |
4.0 |
65 |
44 |
67 |
47 |
6.0 |
84 |
58 |
86 |
61 |
10 |
121 |
86 |
121 |
88 |
16 |
159 |
115 |
160 |
117 |
25 |
208 |
152 |
210 |
154 |
35 |
262 |
191 |
262 |
194 |
50 |
330 |
245 |
331 |
248 |
70 |
418 |
314 |
418 |
316 |
95 |
504 |
381 |
504 |
384 |
120 |
594 |
453 |
594 |
456 |
150 |
683 |
523 |
683 |
528 |
185 |
785 |
603 |
784 |
607 |
240 |
947 |
732 |
945 |
736 |
300 |
1105 |
856 |
1102 |
860 |
400 |
1077 |
1380 |
1079 |
1368 |
1、輻照交聯聚烯烴絕緣地鐵隧道專用電纜連續負載電流是依照IEC-287電纜載流量計算標準進行計算的.并通過修正確定。
Continuous loading current of cable is calculated and revised per IEC-287
2.地鐵隧道專用電纜的長期工作溫度為125℃。
Long-term working temperature of cable is the cable is 125℃
3、布線方式分為接觸與非接觸兩種.其中非接觸指電纜間的相互距離大于二倍的電纜外徑,接觸即指電纜相互靠在一起或相互間距小于二倍的電纜外徑。
4.周圍環境溫度以40℃作為基準溫度。
Environment temperature is supposed 40℃ as basic temperature
環境溫度變化修正系數表
The revised coefficient of the environmental temperature change
環境溫度 E nvironment |
載流量校正系數 Loading current 0f cable revised coefficient |
||||||||
10 |
1 5 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
|
工作溫度 temperature |
1.41 |
1.35 |
1.29 |
1.22 |
1.15 |
1.08 |
1.∞ |
O.93 |
O.88 |
Note. k= Loading current cables
Total number of the cables
(Loading current cables means cables that generating heat when working excet for signal line)
電纜敷設于塑料槽中載流量修正系數表
The revised coefficient of the cable loading current lay in plastic flume
電纜層數 |
同時工作系數 K Coefficient K |
||
1.00 |
O.80 |
0.50 |
|
1 |
0.64 |
0.80 |
0.95 |
2 |
0.50 |
0.75 |
0.90 |
3 |
0.45 |
O.70 |
0.85 |
4 |
0.40 |
0.65 |
0.80 |
The revised coefficient of the cable loading current lay in tube
穿管根數 |
修正系數 |
2 ~ 4 |
0.80 |
5 ~ 8 |
0.60 |
9 ~ 12 |
0.50 |
12 以上 |
0.45 |
1.穿管根數指有負荷發熱的電纜根數。
2.穿管線的體積不超過管體積的40%。
3.當管并列敷設時乘0.95修正系數。
Note:
1) The number of the cable in tube means the number of the cables which generates heat while loading
2)The cable’s volume is not more than 40% of the rube’s volume.
3)When cable laid stand by stand,multiply the revised coefficient with 0.95
機車電纜相關文章
- PTVV鐵路信號電纜
- DTRF,DTREF超薄壁機車電纜?
- WDZ-DCK-100?WDZ-DCK-125?低煙無鹵阻燃鐵路機車電纜
- WDZ-DCEVM-125 特種彈性體絕緣鐵路機車車輛用單芯電纜(電線)
- EFL3GC3G充電樁電纜
- WDZ-DC-H-90,WDZ-DC-ZP-H-90低煙無鹵標準壁厚鐵道客車用電纜
- WDZ-DCYJR-125 3*1.5機車車輛專用電纜
- 橡皮絕緣鐵路機車車輛用電纜
- DCEH/3-100?WDZ-DCYJ/3-125 3*2.5鐵路機車電纜線
- WDZ-DCEVM-125鐵路機車電纜
- DTRF、DTREF、DT-RFE、DT-RFPE軌道交通車輛用電纜
- HSGCEVM?HSGCEVMP?WDZ-DCEVMP鐵道機車車輛用阻燃電纜
- WDZ-DCKP-125鐵路機車車輛專用低煙無鹵電纜
- DCYJZ-150/DCYJZR-150輻照交聯聚烯烴絕緣鐵路機車車輛用電纜
- SLEX-125機車控制電纜
- 單芯屏蔽機車電纜-車載電纜
- 單芯無護套機車電纜-車載導線
- ZR-JEPE22-3R 2*0.75mm2鐵路動車用信號線
- DCXF電纜-DCXF橡皮絕緣機車電纜
- DCK?DCEH?DCJ?DCXVFP 19*1.0,24*1.5地鐵機車用控制電纜
- 機車牽引電機信號電纜